{"id":6686,"date":"2021-03-22T13:04:06","date_gmt":"2021-03-22T13:04:06","guid":{"rendered":"https:\/\/s4r.fr?post_type=product&#038;p=6686"},"modified":"2024-12-23T06:45:39","modified_gmt":"2024-12-23T06:45:39","slug":"thee-electrode-pfa-swagelok-type-cell-1-2","status":"publish","type":"product","link":"https:\/\/s4r.fr\/index.php\/product\/thee-electrode-pfa-swagelok-type-cell-1-2\/","title":{"rendered":"Three-Electrode Electrochemical Analysis Cells with PFA Body, 1\/2\u2033"},"content":{"rendered":"<p><strong>Supplied with :\u00a0<\/strong><\/p>\n<ul>\n<li>SS316 plungers<\/li>\n<li>SS316 spring<\/li>\n<li>SS316 spacer<\/li>\n<\/ul>\n<table style=\"border-collapse: collapse; width: 100%; height: 144px;\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 24.3543%; border-color: #dceefc; background-color: #ffffff; text-align: left; height: 24px;\" colspan=\"3\"><b>Specification<\/b><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 24.3543%; border-color: #dceefc; background-color: #dceefc; text-align: center; height: 24px;\"><b>Component<\/b><\/td>\n<td style=\"width: 20.7338%; border-color: #dceefc; background-color: #dceefc; text-align: center; height: 24px;\"><b>Material<\/b><\/td>\n<td style=\"width: 54.9118%; border-color: #dceefc; background-color: #dceefc; text-align: center; height: 24px;\"><b>Dimensions<\/b><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 24.3543%; text-align: left; height: 24px;\"><strong>Plungers<\/strong><\/td>\n<td style=\"width: 20.7338%; text-align: center; height: 24px;\">SS316L<\/td>\n<td style=\"width: 54.9118%; text-align: left; padding-left: 160px; height: 24px;\">\u00d8 12.7 mm x 45 mm\/55mm<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 24.3543%; text-align: left; height: 24px;\"><strong>Spring<\/strong><\/td>\n<td style=\"width: 20.7338%; text-align: center; height: 24px;\">SS316L<\/td>\n<td style=\"width: 54.9118%; text-align: left; padding-left: 160px; height: 24px;\">Od. \u00d8 11 mm x 15.5 mm<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 24.3543%; text-align: left; height: 24px;\"><strong>Spacer<\/strong><\/td>\n<td style=\"width: 20.7338%; text-align: center; height: 24px;\">SS316L<\/td>\n<td style=\"width: 54.9118%; text-align: left; padding-left: 160px; height: 24px;\">\u00d8 12.7 mm x 1 mm<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 24.3543%; text-align: left; height: 24px;\"><strong>Body<\/strong><\/td>\n<td style=\"width: 20.7338%; text-align: center; height: 24px;\">PFA<\/td>\n<td style=\"width: 54.9118%; text-align: left; padding-left: 240px; height: 24px;\">&#8212;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><a href=\"https:\/\/s4r.fr\/wp-content\/uploads\/2021\/03\/S4R-TSC21.pdf\"><img decoding=\"async\" class=\"alignnone size-medium wp-image-7715\" src=\"https:\/\/s4r.frwp-content\/uploads\/2021\/03\/technical-datasheet-300x75.png\" alt=\"\" width=\"300\" height=\"75\" srcset=\"https:\/\/s4r.fr\/wp-content\/uploads\/2021\/03\/technical-datasheet-300x75.png 300w, https:\/\/s4r.fr\/wp-content\/uploads\/2021\/03\/technical-datasheet-150x38.png 150w, https:\/\/s4r.fr\/wp-content\/uploads\/2021\/03\/technical-datasheet.png 334w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Our three-electrode electrochemical analysis cells, made in France, are designed for advanced electrochemical studies, offering exceptional precision and reliability. Each cell\u2019s body, sourced from Swagelok, ensures superior quality, durability, and dependability, even in complex and challenging environments. These disassemblable cells facilitate effortless assembly, disassembly, and cleaning, ensuring rapid recovery of electrodes after each test. Compact yet robust, they are the ideal solution for researchers and engineers conducting detailed electrochemical analyses.<\/p>\n<p>Equipped with a body made from PFA supplied by Swagelok, these cells deliver outstanding chemical inertness. They are especially suited for studies involving corrosive electrolytes and high-voltage applications. Their exceptional chemical resistance makes them indispensable for research into supercapacitors and Li-, Na-, and K-ion battery technologies.<\/p>\n","protected":false},"featured_media":6709,"template":"","meta":[],"product_cat":[53],"product_tag":[],"_links":{"self":[{"href":"https:\/\/s4r.fr\/index.php\/wp-json\/wp\/v2\/product\/6686"}],"collection":[{"href":"https:\/\/s4r.fr\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/s4r.fr\/index.php\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/s4r.fr\/index.php\/wp-json\/wp\/v2\/media\/6709"}],"wp:attachment":[{"href":"https:\/\/s4r.fr\/index.php\/wp-json\/wp\/v2\/media?parent=6686"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/s4r.fr\/index.php\/wp-json\/wp\/v2\/product_cat?post=6686"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/s4r.fr\/index.php\/wp-json\/wp\/v2\/product_tag?post=6686"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}